Gas adjustment
1
Change the injector of the burners.
Injector
2
Adjustment of minimum level of the flame.
Do not dismantle the tap shafe:
Remove the pan support, Burner lid and Flame spreader.
Unscrew the injector using a 7mm box spanner and
replace it with the stipulated injector for new gas
supply. Carefully reassemble the all components.
After injectors are replaced, it is advisable to strongly
tighten the injector in place.
Turn the taps down to minimum.
Remove the knob from the tap and place a small
Control handle
bladed screwdriver in the centre of the tap shaft.
The correct adjustment is obtained when the flame
has a length of about 3 - 4 mm.
Tap
- For butane / propane gas, the adjusting screw must
Sealing ring
-
be tightly screwed in.
Refit the control knob.
-
Make sure that the flame does not go out by
quickly turning from maximum flow to minimum
flow. If it does then remove the control knob and
make further adjustments to the gas flow, testing it
again once the adjustment has been made.
Repeat this process for each one of the gas taps.