Descargar Imprimir esta página

Hansgrohe M5316-H240 73870000 Modo De Empleo/Instrucciones De Montaje página 6

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 8
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
• The plumbing codes applicable in the respective countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Mixer stiff
Mixer dripping
Water escaping in area of swivel spout
Water escaping at the threaded base
Hot water temperature too low
4
English
Symbol description
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
- connection hoses not completely screwed into basic
body
- O-ring at the connection hose defective.
- Hot water limiter incorrectly set
Assembly (see page 31)
Do not use silicone containing acetic acid!
Adjustment (see page 33)
To adjust the hot water limiter. Using a hot water limiter in combination
with a continuous flow water heater is not recommended.
Operation (see page 38)
• Hansgrohe recommends not to use as drinking water the first half
liter of water drawn in the morning or after a prolonged period of
non-use.
• Minor leaking may occur briefly at the spout when opening the
fitting via the lever.
Cleaning (see page 34)
Maintenance (see page 35)
The check valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least once
a year).
Dimensions (see page 36)
Flow diagram (see page 36)
Normal spray
Regular
Spare parts (see page 39)
XXX = Colors
000 = chrome plated
800 = stainless steel optic
Special accessories (order as an extra)
F12 extension #43333000 (see page 38)
Test certificate (see page 40)
Remedy
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter

Publicidad

loading

Este manual también es adecuado para:

M5316-h210 73871000