Special features
Adaptive Intelligent Recovery (AIR)
This feature allows the thermostat to "learn" how long the heating/cooling system takes to reach
programmed temperature settings, so the temperature is reached at the time you set. For example:
Set the Wake time to 6:00 am, and the temperature to 70°. The heat will come on before 6:00 am,
so the temperature is 70° by 6:00 am. The message "Recovery" is displayed when the system is
activated before a scheduled time period.
Note:
System setting function 0530 controls AIR. See "User setup" on page 35.
Compressor protection
This feature forces the compressor to wait a few minutes before restarting, to prevent equipment
damage. During the wait time, the message "Wait" is displayed on screen.
Auto changeover
This feature is used in climates where both air conditioning and heating are used on the same day.
When the system is set to AUTO, the thermostat automatically selects heating or cooling depending
on the indoor temperature. Heat and cool settings must be at least 3 degrees apart. The thermostat
will automatically adjust settings to maintain this 3-degree separation.
Note:
System setting function 0300 controls Auto changeover.