not blocked in any way. Also, do not mount the passive radiator part of the
housing attached to a wall, ceiling or floor, but at a distance that allows air to
pass.
Inverter installation
Environmental conditions
Keep the inverter in a dry and ventilated environment. Keep the inverter
away from moisture, dust, heat, sunlight, volatile gas or high salinity.
Caution
The operating temperature range of the product is -26˚C ~ + -26°C ~ +80°C.
Do not overload the inverter in conditions with temperatures above 40˚C.
If you use the inverter excessively at temperatures above 40˚C, reduce the
consumption by 10% for each degree above 40˚C.
The optimum operating temperature of the inverter is between + 20˚C ~ +
30˚C.
If used at temperatures above 30˚C, the battery life will decrease considerably.
Below 20˚C the electric storage time will decrease.
Keep safety distance
The inverter must be mounted at least 60 mm from the surrounding walls,
with the cooling radiator unobstructed by other objects.
Do not cover the side panels of the inverter to ensure efficient cooling and to
avoid overheating.
The electric cables connection
Make sure the power button of the inverter is OFF.
Observe the polarity of the wires and do not connect them in reverse to avoid
shorting the inverter.
Follow these steps to connect the inverter cables:
1. Switch off the inverter with the ON / OFF button.
2. Connect the wires to the battery terminals respecting the polarity.
3. Make sure that the 2 cables are connected tightly, to avoid overheating.
4. Connect the load to the Schuko socket.
User manual
6