3. MEASURING
Apply a reflective mark to the object being measured. Depress the "MEAS" button and align
the visible light beam with the applied target. Verify that monitor indicator lights when
the target aligns with the beam. Then the current mode is the last time mode. If you need
to change the mode, release the "MEAS" button and press the "MODE" button before the
instrument auto power off(released the "MEAS" button this instrument will auto power off in
10 sec) will converted between "RPM" and "REV"(revolution). Selected the mode of you need,
depress the "MEAS" start measures.
Press the "MEM" button can reading the Max, Min and Last value of last time measuring.
4. MEASURING CONSIDDERTATION
*Ref lective mark
Cut and adhesive tap provide into approx 12mm (0.5") squares and apply one square to each
rotation shaft.
a. The non-reflective area must always be greater than the reflective area.
b. If the shaft is normally reflective, it must be covered with black tape or black paint before
attaching reflective tape
c. Shaft surface must be clean and smooth before applying reflective tape.
*VERY LOW RPM MEASUREMENT
As it is easy to get high resolution and fast sampling time, if measuring the very low RPM
values, suggest user to attach more "REFLECTIVE MARKS" averagely. Then divide the reading
shown by the number of "REFLECTIVE MARKS" averagely. Then divide the reading shown by
the number of "REFLECTIVE MARKS" to get the real RPM.