2.3.1 Removing the Middle Spring
If the weight of the equipment that the AV table is going to hold is between 27 and 47 kg the middle spring needs
to be removed is is done in the following manner:
1.
Unscrew the table plate; it is attached with 4 screws on the bottom side (only on AV1).
2.
Remove the table plate (only on AV1).
3.
Please put on gloves when touching the springs
4.
In each side of the table there are metal rods screwed into the frame, unscrew these two metal rods.
5.
Push the springs to one end and lift out the other metal rod
6.
Remove the screw in the middle spring on the opposite side of the end that is lifted.
7.
Pull out the middle spring.
8.
Push the two remaining springs to the bottom side.
9.
Move the other metal rod in place and screw both metal rods in place again.
10. Place the table plate back on and attach it underneath with the 4 screws.
8
AV1 AND AV5 USER MANUAL