Care and Cleaning
To clean, wipe down with a damp cloth and towel dry.
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will
be voided.
Troubleshooting
NOTE: Refer to the service parts section in this manual for a
detailed drawing showing the location of the parts listed below.
Problem
There are leaks from the
handle.
The aerator leaks or has a
reduced water flow.
The water will not shut off
completely.
The sink drain at the base of
the sink is leaking.
All manuals and user guides at all-guides.com
Possible Cause
□ The bonnet nut is loose.
□ The O-ring on the cartridge is
dirty or damaged.
□ The aerator is dirty or mis-fitted.
□ The cartridge may be clogged.
□ The locking nut is loose or
cartridge is not positioned
correctly.
□ The sink surface is rough or
irregular.
□ Tighten the bonnet nut.
□ Clean or replace the O-ring.
□ Remove the aerator and check for
debris.
□ Remove the cartridge and check for
debris.
□ Ensure the aerator is properly
installed.
□ Remove the handle and cartridge to
check the rubber seat and spring.
□ Tighten the lock nut.
□ Clean or replace.
□ Apply additional silicone sealant to
the beveled side of the drain flange.
□ Retighten and test for leaks.