About the controlson the dehumidifier.
4 houror 2 hour
High,Medium
delayoff
andLowfan
indicator lights
indicator lights
Cleanthe Filter Continuous operation on
indicatorlight
indicator light
4 hour
2 hour
High
Mediul
Low
Humiditg
%
o-
Continuous
Cteen the Filter
e,
Bucket
Full
Power On
Bucket F ull lightindicates
bucketneedsto beemptied
or is not inplaceinthe unit
]
PowerOn
indicator light
4
Controls
NOTE:When the bucket is full or removed, the
controls cannot be set.
Power Pad
Pressto turn the dehumidifier on and off.
Filter Timer
After 250 hours of operation, the CleantheFilter
indicGtorlight will glow to remind you to clean
the filter. Removethe filter and clean it.
Pressto turn off the Cleanthe Filterlight.See
the Careand Cleaningsection.
Humidity Set Control Pads
The humidity level can be set within a range of
35% RH(RelativeHumidity) to 80% RH(Relative
Humidity) in 5% increments or Gt COlor
continuous operation. To set the unit for
continuous operation, press the T pad until
the screen reads CO.
NOTE:If CO(Continuous)is selected, the
dehumidifier will operate continuously at
its maximum dehumidification settings if
attached to a hose to drain or until the bucket
isfull.
Fordrier air, press the V pad and set to
a lower percent value (%).
Fordamper air, press the A pad and set
to a higher percent value (%).
Other ,Features
When you first use the dehumidifier, set
the humidity control to 45% or 50%. Allow at
least 24 hours for the dehumidifier to achieve
the humidity level. If you still have dumper air
than desired, set the humidity level to a lower
setting or select Continuous for maximum
dehumidification.
Display
Shows the set % humidity level while setting,
then shows the actual (+/- 5% accuracy)
room % humidity level.
Fan Speed Pad
Controls the fan speed.
Press to select either High,Medium or Lewfan
speed.
Set the fan control to Highfor maximum
moisture removal. When the humidity
has been reduced and quiet operation is
preferred, set the fan control to Medium
or Low.
Delay Off
While the dehumidifier is in operation, press
this pad to set it to automatically turn off in 2
hours or 4 hours.
BUCKET FULL Light
Glows when the bucket is ready to be emptied, or
when the bucket is removed or not replaced in the
proper position.
Alarm
If the bucket isfull or missingfor more than 3
minutes,an alarm will sound for about 10 seconds
to remindyou to empty and replacethe bucket.
AutoShutOff
The Water LevelControl Switch shuts off the
dehumidifier when the bucket isfull, or when
the bucket is removed or not replaced in the
proper position. NOTE: Fan will continue to run
approximately 3 minutes after bucket is removed.
AutoDefrost
When frost builds up on the evaporator coils,the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Power Outage
In the case of a power outage or interruption, the
unit will automatically restart, in the settings last
used, after the power is restored.