GB
UNM-STH 650-10-180
Table of contents - Part 1
1.1
General information .................. 4
1.2
Scope of delivery ...................... 4
1.3
Conventional use ...................... 4
1.4
Technical data .......................... 4
1.5
Components............................. 4
1.6
Maintenance............................. 5
1.7
Compressor inspections ............. 5
1.8
EC Declaration of Conformity ...... 6
The specified illustrations appear at the be-
ginning of the Operating Instructions.
1.1
General information
Observe the safety instructions!
Read the Instruction Manual!
1.4
Technical data
Suction capacity
Effective delivered volume
Voltage
Electric protection, delayed-action
Motor output
Max. operating speed
Compression final pressure
Switch-on pressure
Vessel capacity
Maximum permissible working overpressure of vessel
1
Oil quantity
L
as per DIN 45 635 T 13, 1 m distance
pA1
Overall dimensions: width x depth x height
Weight
Max. number of switching cycles
Operation/Downtime ratio
Min. distance to wall
Ambient temperature
1.
Initial filling: mineral oil up to 10 °C. Under 10 °C, use fully synthetic oil.
1.5
Components
01
Compressor unit
02
Intake filter
03
Oil filler plug
04
Oil drain screw
05
Oil inspection glass
I/4
Note: Read and memorise part 2 of the in-
struction manual!
Subject to technical modifications. Illustra-
tions may deviate from the original.
1.2
Scope of delivery
– Compressor with instruction manual
– Documents accompanying compressed air
vessel
1.3
Conventional use
The compressor is designed for generating
and storing compressed air only. Com-
pressed air is only suitable for compressed
air tools/devices/machines.
Any other type of use is considered contrary
to the intended use.
06
Connecting hose
07
Check valve
08
Vessels 1
09
Vessels 2
10
Ball valve at condensate drainage point
1
650 l/min
520 l/min
400 V
16 A
4.0 kW
950 rpm
10 bar
8 bar
2 x 90 l
11 bar
1.34 l
83 dB(A)
1200 x 800 x
mm
1240
175 kg
10 1/h
60:40 --
40 cm
5-35 °C