Test procedure
- Connect the required 4 mm test plugs of the EVSE test lead to your TV 456,
- Select CP mode "A" with the slide switch,
- Connect the EVSE test cable to the type 2 plug of the charging station,
- Select CP mode "B" with the slide switch, the charging station should display "ready to charge",
- Select CP mode "C" with the slide switch, the charging station should start charging,
- carry out all measurements in the active phase of the charging station (voltage and the like),
- after you have performed all measurements, select CP mode "A" with the slide switch to end the
charging process,
- Disconnect the test cable from the charging station.
Proximity Pilot (PP) Status (Cable Simulation)
The EVSE test lead is internally configured (680 Ohm between PP and PE) to carry a current of
20 A.
Control Pilot (CP) State (vehicle simulation)
The CP mode slide switch can be used to simulate different vehicle states. The vehicle states are
simulated with different resistors connected between the CP and PE conductors. The relationship
between resistance and vehicle state is shown in the following table.
Vehicle condition
A
B
C
E
18
State-Creation
Vehicle not connected
Vehicle connected, not
ready for charging
Vehicle ready for
charging, connected,
ventilation g not required
CP error "E
CP-PE
Resistor
Open (infinite)
2.74 kΩ
882 Ω
0 Ω
Testboy
Notes
CP voltage
± 12 V at 1 kHz
+9 V / -12 V at
1kHz
+6 / -12 V at
1kHz
0 V
®
EVSE Adapter