ENGLISH
Page 20
9.
Rinse the sensor in clean tap water for 1 minute. Shake off excess
water.
10. Connect the sensor BNC connector to the electronic circuit board.
Section 7.
Sensors must be stored indoors, in water, over the winter when the
pool is not in use.
1.
Turn off pump and filtration system at the breaker. Pump needs to be
in auto, NOT service mode.
2.
Close the valves if needed.
3.
Fill the sensor storage tubes with pool water and set nearby the Jandy
TruSense.
4.
Remove Jandy TruSense top cap.
5.
Disconnect the pH and ORP sensor BNC wires from the Jandy
TruSense electronic circuit board.
6.
Loosen and remove pH and ORP sensors from compression fittings.
7.
Carefully place the sensors in the sensor storage tubes, DO NOT touch
the glass bulb at the end of the sensors, see Figure 13.
8.
Store sensors indoors in a dry environment.
9.
Remove water from Jandy TruSense.
Figure 13.
Store Sensors
Jandy
Winterization
TruSense Water Chemistry Analyzer | Owner's Manual
®