15. Troubleshooting
m Attention!
Pull out the mains plug before carrying out any cleaning or maintenance work.
The following table shows fault symptoms and describes remedial measures in the event of your product failing to
work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault
Saw blade without pins
loosens after switching
off the engine
Motor does not start
Saw blades brake
Saw blade oscillates,
not aligned straightly.
Possible cause
Saw blade clamping screw of the
holder (27) not tightened enough
Extension cable defective
Connection to the motor or switch
not OK
Motor or switch faulty
Tension set incorrectly
Load too high
Incorrect saw blade type
Workpiece not fed straightly
Holders not aligned
www.scheppach.com
Remedy
Tighten the saw blade clamping screw of the
holder (27)
Replace the extension cable
Have this checked by an electrician
Have this checked by an electrician
Set correct tension
Feed workpiece more slowly
Use correct saw blades
Avoid lateral pressure
Open the screws that fasten the holders.
Bring the holders into the vertical position
and tighten the screws again.
GB | 39