TROUBLESHOOTING TABLE
Error message / error
When switched on, the
machine does not start
The machine does
not provide sufficient
performance
Low or no cooling water feed
Motor does not start
Diamond blade wobbles
Segments are coming off
86
Possible cause
Troubleshooting
Mains plug is loose
Check proper connection to
mains
Mains plug is defective
Check the mains plug
for operability, replace if
necessary
Loose connection in the
Have the entire electric
electric system
system of the machine
checked
The drive motor is
Have the drive motor
defective
checked, replace if necessary
The main switch is
Have the main switch
defective
checked, replace if
necessary.
The mains plug is too long,
Observe the prescribed
cord reel is wound up
length of the mains plug .
Unwind the cable cord
Capacity of the local mains
Pay attention to and observe
is insufficient
the ma chine connection data
The drive motor does not
Have the drive motor
maintain the rotation
checked, replace if necessary
speed
The water pump sucks air
Fill the tank with water;
swivel the pump with the
suction side downwards
Hose are clogged
Clean the hoses
Hoses bent
Check hose layout
A hose is leaky or
Replace or re-attach the hose
detached
properly
The water pump wheel or
Clean the pump wheel or
strainer is polluted
strainer
Water pump does not
Have the electric supply line
function
checked, replace if necessary
Mains plug is not properly
Check the mains plug for
plugged.
proper connection
A fuse at the construction
Check fuses
site distribution board has
tripped
Blade tension is poor
Return the diamond blade
Overheating, cooling is
Check cooling water line
poor
Segments are soldering on
Personnel
Operating personnel
Qualified electricians
Operating personnel
Qualified electricians
Operating personnel
Qualified electricians
Operating personnel
Manufacturer
Operating personnel
Manufacturer