Refresh-o-mat HD
6
Technical description
6.1
General description
The ultrasonic cells diffuse the air-conditioning cleaning agent into a fine
spray. The spray is directed through the hose by a fan to the suction open-
ings of the air-conditioning system.
The Refresh-o-mat switches off automatically in the following events:
The fluid reaches the minimum level
The tank is overfilled (the Refresh-o-mat does not start if the tank is too
full)
A temperature of 65 °C is exceeded
6.2
Control panel
Item in
fig. 3,
Description
page 3
1
HIGH
TEMPERATURE
2
READY/ON
3
HIGH LEVEL
4
START/STOP
EN
Explanation/function
Red LED
Lights up if the interior temperature exceeds
65 °C. The device stops automatically.
Green LED
Flashes while the tank is being filled up
Lights up while it is being cleaned
Green LED
Lights up if the tank is overfilled with fluid. The
device stops automatically.
Switches the device on or off.
Technical description
11