SOLUTION TEMPERATURE
The temperature control is factory set to maintain the solution at 41º C ± 1º
(106°F ±2°). At this temperature the bioremediation process is at its most efficient
level, cleaning is faster and operator comfort is at its best.
START UP INSTRUCTIONS
Please be sure to read and observe, the "SAFETY INSTRUCTIONS" at the
beginning of this manual. Detailed start-up instructions can also be found at
www.biocircle.com
1. Remove the BIO-CIRCLE™ Parts Cleaning System from its packaging and
check for any shipping damage. Should any be detected, DO NOT connect
the machine but report the damage to the transport carrier and to J. Walter.
The original packaging must be retained.
2. Open the sink. A gas spring will maintain it in the open position.
- Remove all packaging material around the unit and from inside the tank.
(ex.: from underneath or behind pump/heater coil)
- Ensure filter bowl (D) is tightened. (Hand tighten only).
Place unit indoor, on a smooth level surface away from exposure to direct
sunlight. Use only genuine Bio-Circle L™ (55-A 007, 20 liters/5.3 gal. or
55-A 008, 208 liters/55gal.) and Bio-Circle Ultra™ (55-A 107, 20 liters/5.3
gal. or 55-A 108, 208 liters/55gal.) cleaning solution.
When filling the unit from a drum, ensure the transfer pump being used is clean
and close the drum once done.
Fill the tank to normal operating capacity of up to 140 liters/37 gal. Refer to level
lines shown on page 8.
Note: Open the container's vent holes and pour slowly to prevent splashing
and excessive foaming of Bio-Circle L™ or Bio-Circle Ultra™ liquid.
3. Plug power cord into properly grounded 3-prong, 120V, 60Hz, outlet protected
by a class A GFCI.
4. Turn main power switch (E) to "I".
Note: Do not turn ON the main power switch (E) and the cleaning pump
switch (F) with no liquid inside the machine.
5. Allow the heater coil to warm Bio-Circle L™ or Bio-Circle Ultra™ solution
to working temperature for optimal cleaning efficiency. This can take up to 5
hours.
Once the solution has reached its proper working temperature of 41ºC/106°F,
periodically, the heater will turn itself ON automatically to maintain the proper
working temperature.
Never turn OFF the BIO-CIRCLE™ unit except for servicing.