TROUBLESHOOTING
Problem
Possible cause
No power after
The control panel cable
switching on the
is not connected to the
on/off switch.
board.
Heating before adding
water and the thermostat
was overloaded.
The control panel
The temperature sensor
display shows E1.
cable is not connected to
the board.
No heating up
The start button was not
after finishing the
pressed long enough.
setting steps.
Cable not properly
connected.
The water is not
The outlet tap is not
pumped out of
open.
the outlet tap.
Air or bubbles in the
pump.
The wort is not
Air or bubbles in the
pumped out.
pump.
Filter pipe or filter
container are clogged.
The wort is too thick and
sticky.
Method of solution
Connect the control panel cable to the circuit
board.
Wait until the brewing equipment has cooled
down to below 175 °C.
Reconnect the sensor cable to the board.
Press and hold the start button for 3 seconds.
Connect the cable properly.
Open the outlet tap.
Make sure the water level is above the
discharge opening, stop the pump, open one
of the valves and open the discharge tap to let
the air escape from the pump.
Make sure the water level is above the
discharge opening, stop the pump, open one
of the valves and open the discharge tap to let
the air escape from the pump.
Switch off the brewing equipment, remove all
the wort as soon as it has cooled down and
clean the filter pipe and filter container.
Top up with water.
EN