OPERATING INSTRUCTIONS
NOTE: The first time you operate the unit, it may smoke slightly. This is due to the residual cleaning agents
used to clean the element when the heater is manufactured. This is normal and does not indicate a
problem with the unit. This condition will stop after the heater has been in operation for a few minutes.
Automatic Thermal Limit: This heater is equipped with a thermal limit which will automatically shut off
the heater in the event of overheating. Should the thermal limit activate an ALARM will be activated. The
alarm will be a beeping sound; the display will show "E3" and the red "POWER" light will flash. The cause
of the overheating should be determined before further operation. As the heater cools, the thermal limit
will automatically reset the display will show "E3" indicating the heater is non-operational. Should the unit
overheat and activate the thermal limit, to return heater to operating mode will require user to press
power button on remote or heater after allowing the heater to cool for 15-20 minutes user must reset
control to desired wattage output and room temperature. Do not continue to use heater if it repeatedly
overheats to cycle the safety thermal limit as this could lead to permanent damage to heater or a fire.
Automatic Fan Delay: The heater is provided with an automatic fan off delay. As the room ambient
reaches the preset temperature level of the heater control will de-energize the heating element within
the heater while the fan continues to run for approximately 3 minutes to allow the heater to cool.
MAINTENANCE
USER CLEANING INSTRUCTION:
1. Turn off power to heater
2. After the heater has cooled, a vacuum cleaner with brush attachment may be used to remove dust and
lint from exterior surfaces of the heater including the grille opening. Compressed air may also be used to
blow out dust from inside heater.
3. With a damp cloth, wipe dust and lint from grille and exterior surfaces. Be careful not to let the water
enter the inside of appliance.
4. To protect the enclosure, don't splash water onto the heater, and never use solvents to clean the
heater.
5. Return power to heater and check to make sure it is operating properly.
Maintenance Cleaning Instructions:
(To be performed only by Qualified Service Personnel)
At least annually, the heater should be cleaned and serviced by a qualified service person to assure safe
and efficient operation. After completing the cleaning and servicing, the heater should be checked for
proper operation.
The remote control is powered by 2 AAA batteries. These should be replaced periodically or at least
annually.