INSTALLATION
Installing/Replacing the lamp
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one EHJ 24 V/250 W GX-6.35 lamp.
During the operation, the lamp reaches temperatures of up to 920° C.
Procedure:
Step 1: Unscrew the fixation screws of the service lid on top of the housing.
Step 2: Remove the service lid.
Step 3: If replacing the lamp, remove the old lamp from the lamp-socket.
Step 4: Insert the new EHJ 24 V/250 W GX-6.35 lamp into the lamp-socket.
Step 5: Replace the service lid and tighten the screws.
Inserting/Exchanging gobos
If you wish to use other forms and patterns as the standard-gobos, or if gobos are to be exchanged, please
follow the instructions below:
Unscrew the fixation screws and remove the top of the housing. The gobo is located in the toothring.
Remove the fixation-ring with an appropriate tool. Remove the gobo and insert the new gobo. Press the
fixation-ring together and insert it in front of the gobo.
When installing metal gobos, please make sure that the mirror-inverted side points to the lamp. When
installing glas-gobos, please make sure that the coated side points away from the lamp.
Replace the housing top and tighten the screws.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened service lid!
DANGER!
Install the gobos with the device switched off only.
Unplug from mains before!
16/38
00026479.DOC, Version 1.3