Descargar Imprimir esta página

Nilfisk Hybrid Compact/Pegasus-P MD422 Serie Instrucciones De Uso página 20

Publicidad

Idiomas disponibles

Idiomas disponibles

9. Maintenance, Trouble shooting,
Service
Service may only be carried out by authorized and
qualified personnel.
CAUTION
The system must only be serviced when
there is no voltage or pressure on the sys-
tem
.1.
Turn off the main switch at the control box
2. Open a water outlet to depressurise the system
.
9.1. Installation Instruction for Flow Switch
There is a dot on one of the nut surfaces on the
sensor. This is used to position the contact point of
the sensor in relation to the direction of flow of the
medium.
This marking must be located within an angle of +/-
30° perpendicular to the direction of flow, as shown in
the example.
Mark
Flow
Diagram of sensor fitted in a pipe.
20
30°
Loctite 577 is used at the factory to seal the thread,
but packing yarn/packing tape can also be used.
9.2. Components
9.2.1.
Pumps/motor
Pumps/motor are maintenance free.
9.2.2.
Control system
Maintenance free
If defective: Call a service technician
9.2.3.
Flow switch
Maintenance-free.
If defective, replace the flow switch.
1. Press "0" on the control panel to stop the system.
2. Remove the cover.
110000973
3. Turn the "rinse/foam" handle to foam position.
4. Activate the spray handle on the outlet hose so
water runs out.
5. Check that the flow switch is turned the correct
way (the wire must follow the follow direction).
6. Turn the brass screw at the bottom of the hole
until a green diode lights up.
7. Close the spray handle again and check that the
red diode lights up.
8. Mount the cover.
110002490
30°
110002491

Publicidad

loading

Productos relacionados para Nilfisk Hybrid Compact/Pegasus-P MD422 Serie

Este manual también es adecuado para:

Hybrid compact/pegasus-p md421