Descargar Imprimir esta página

Craftsman 921.16472 Manual Del Propietário página 8

Ocultar thumbs Ver también para 921.16472:

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE
5. Clean thecheck v alve withwarm soapy w ater a ndmake sure
__
To avoid personal injury, always shut off
and unplug the compressor
and relieve all air pressure
from the system
before performing any service
on the air
compressor.
Regular maintenance will ensure trouble-free
operation.
Your electric powered air compressor represents high-quality
engineering and construction;
however, even high-quality
machinery requires periodic maintenance. The items listed below
should be inspected on a regular basis
DRAiNiNG THE TANK
Drain the moisture from the tank (for instructions, see
"Shutdown" in the operating instructions section).
__Condensation
will accumulate
in
the tank. To prevent corrosion
of the tank from the
inside, this moisture
must be drained at the end of
every workday.
Wear protective eyewear.
NOTE:
In cold climates, drain the tank after each use to reduce
problems with freezing of water condensation.
TO REPLACE OR CLEAN CHECK VALVE
1.
_II,_RISK
OF INJURY. This unit starts
automatically.
ALWAYS
shut off the compressor,
remove the plug from the outlet, and bleed all
pressure from the system before servicing
the
compressor, and when the compressor
is not in use.
Do not use the unit with the shrouds
or belt guard
removed.
Serious injury could occur from contact
with moving parts.
Turn air compressor off, remove the power cord from the
outlet or lock out the power supply and relieve all the air
pressure from the tank (refer to "Shutdown" in Operating
Instructions). Make sure the compressor has cooled down
before servicing.
2.
Using the appropriately
sized wrench, loosen
the compression
nuts
(A) on the check valve
(B). Gently move the
transfer tube (C) and
bleeder tube (D) out of
the way.
3.
Making note of the
orientation for
reassembly, unscrew
the check valve from the
tank (counterclockwise)
using the appropriately
sized wrench.
4.
Using a pencil or
screwdriver, carefully
push the valve disc up
and down. If the valve
disc does not move freely
up and down, the check
valve needs to be cleaned
or replaced.
C
A
Check valve
Screwdriver
pencil
to dry thoroughly before reinstalling.
If the disc valve still
does not move freely up and down, it will need to be
replaced.
6.
Apply thread sealant to the check valve threads and reinstall
into the tank by turning clockwise. Make sure it is the
same orientation as when it was removed.
7.
Replace the bleeder tube and tighten compression nuts.
8.
Replace the transfer tube and tighten compression
nuts.
CLEANING THE AiR FILTER
A dirty air filter will
reduce the compressor's
performance
and life. To
avoid any internal
contamination
of the pump,
the filter should be cleaned
frequently, and replaced on a
regular basis. Felt filters
should be cleaned in warm,
Airfilter
soapy water, rinsed, and
allowed to air dry before
reinstattation. Paper filters
should be replaced when
dirty. Do not allow the filter to become filled with dirt or paint. If
the filter becomes filled with paint, it should be replaced. Direct
exposure to dirty conditions or painting areas will void your
warranty.
CHECKING THE RELIEF VALVE
Pull the tank safety valve daily to ensure that it is operating
properly and to clear the valve of any possible obstructions,
TESTING
FOR LEAKS
Check that all connections are tight. A small leak in any of
the hoses, transfer tubes, or pipe connections will substantially
reduce the performance of your air compressor.
If you suspect a
leak, spray a small amount of soapy water around the area of the
suspected leak with a spray bottle. If bubbles appear, repair or
replace the faulty component. Do not over tighten any
connections.
STORAGE
®
Before storing the compressor for a prolonged period, use an
air blow gun to clean all dust and debris from the compressor.
Disconnect the power cord and coil it up. Pull the tank safety
valve to release all pressure from the tank. Drain all moisture
from the tank. Clean the filter element and filter housing; replace
the element if necessary. Drain the oil from the pump crankcase
and replace it with new oil. Cover the entire unit to protect it from
moisture and dust.
SERVICE
INTERVAL
Perform the following
maintenance
at the
Daily or after
intervals indicated below,
each use
When used in
Inspect air filter (clean or replace as necessary)
dusty
conditions
Operate the tank safety valve
o
Drain tank
o
200-2798

Publicidad

loading