Descargar Imprimir esta página

Nordelettronica NE319 Instrucciones Para El Uso página 4

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

CONTROL PANEL NE319
GB
CONTROLS:
Push button for turning
INTERNAL LIGHTS on or off
Push button for turning
EXTERNAL LIGHTS on or off
(*) Green light colour active load, yellow light colour deactive load.
SCREENS:
See page 2 of the manual for details about the graphics.
In the main screen always displays the date, time
temperature when the external temperature sensor is connected. If the temperature probe is faulty the wording "
appear
in the position of the temperature value.
This symbol appears when
This symbol appears when the service battery is coupled to the car battery
This symbol appears when the battery charger NE287 signals the overtemperature battery alarm (t > 50°C)
The charge is momentarily interrupted and the alarm will be reset itself when the battery cools.
This symbol indicates that the alarm clock is enabled with related time. The alarm clock rings at the pre-set time
for 1 minute every 10 minutes; press any button to stop it ringing.
Pressing these buttons to view the pages:
- the voltage for the service batteries B2 and vehicle batteries B1
- the level linear percentage %
(0,33,66,100)
- the programming page (press this button "
A bell is shown next to each indication
flashes.
If the tank is wrongly connected will show "
This written appears when there is an error communicating with NE196 shunt.
PROGRAMMING
In the programming page use the arrow keys
enter the page and select the value to be changed (the value flashes) . Now using the arrow keys change the selected value.
While the this key
(
)
exits the function by saving the values
The functions available are:
- Date and time regulation.
- Alarm clock time enabling and regulating.
-
Alarm enabling:Tank S1 empty or Recovery tanks R1 full.
When the alarm occurs in the panel buzzes (if enabled) intermittently for 5 sec. and at the same time shows the TANK
screen with the corresponding bell flashing.
-
Alarm enabling: Car battery (B1) less than 11,8V or Service battery (B2) less than
The minimum voltage of battery alarm services (V-OFF) can be set from 10,0V to 11,7V.
When the alarm occurs in the panel buzzes (if enabled) intermittently for 5 sec. and at the same time shows the
BATTERY screen with the corresponding bell flashing.
- Enabling the confirmation beep button pressed, and alarm buzzers
- Page info: displays the version of the panel and the shunt.
CONSUMPTION:
To turn on the control panel you must touch for 1 second the glass panel below the display.
The panel after 30 sec. switches to standby mode by turning off all symbols except the keys
for 1 second the glass panel below the display.
On stand by (no active controls and no back lighting) the control panel with shunt NE196 consumes a total of approx 120mA.
When the key
is pressed the control panel turns itself off and total consumption is reduced to just 6mA.
If the service battery voltage drops below
the control panel turns itself off, together with all live parts.
CONNECTIONS:
The back of the panel has a connector for serial connection (CON3), a connector for the optional external temperature probe
(
TEMP OUT
) and a connector for the optional remote internal temperature probe (
If connecting the remote internal temperature probe must be cut and remove the temperature sensor of the pc-board
positioned between the support and the frame.
MEMORY BATTERY:
A buffer battery (LITHIUM 3V CR2032) is located on the back of the panel (removing the cover) to maintain the time in the
event of a power breakdown.
(*)
(*)
service battery voltage,
the 230V mains is connected
(from 0 to 100)
in the recovery tanks R1.
if the relevant alarm is enabled. When the alarm is present the bell
(
) (
V-OFF voltage set in the programming menu, range 10,0V ÷ 11,7V)
(
Push button for turning
PUMP on or off
(*)
Push button for turning
AUX on or off
(*)
and internal temperature. Also displays the external
in the drinking water tank S1 and the level percentage %
" to enter)
" in the position of the value
) to
view the different settings. Press the enter key
4
BAT
(
V-OFFn (10,0V ÷ 11,7V).
. Keys light up when you touch
TEMP IN
).
GB
" will
)
repeatedly to
, after 1 minute

Publicidad

loading

Este manual también es adecuado para:

Ne319-f1463.319.02