5. Product description
5.2 Operating elements
Key
Description
ON/OFF
REWEIGH
HOLD / RELEASE
TARE
ZERO
CLEAR
kg/lb
ENTER
SHIFT LEFT
Up / Down
Function
Switches the scale on or off.
f
Recall the weighing algorithm.
f
Pressing the button with the HOLD display switched off
f
displays the last current weight and „HOLD".
Pressing the button with the HOLD display on will release
f
the weight and turn off the HOLD display.
This button is not active in BMI mode.
f
If the weight is below the maximum value (ASTART value),
f
the manual tare setting is called up.
If the weight is above the maximum value, the tare functi-
f
on is called up.
In TARE mode, NET (net) and GROSS (gross) are displayed.
f
The maximum TARE value is 4,000 kg / 9,000 lb.
f
Resets the scale to zero.
f
Resets to zero within three seconds.
f
This function is only possible when the weight is stably
f
displayed.
Zeroing up to 2% of the full weight.
f
CLEAR: Clear input/display
f
kg/lb: Switch between kg and lb
f
The value of the last parameter entered is accepted and
f
the next step is continued.
Pressing this key for a long time during the scale start-up
f
process causes an identification entry (Enter ID) to be
displayed (pre-parameter mode).
The flashing digit or number is shifted to the left.
f
This key increases or decreases the value of the flashing
f
digit or number.
29