3. Operation
Manual vane angle
1 Select "Maintenance" from the
Main
Main menu
Maintenance
Initial setting
Service
Main display:
Cursor
Page
F1
F2
F3
F4
2 Select "Manual vane angle" with
Maintenance menu
Auto descending panel
Manual vane angle
Main menu:
Cursor
F1
F2
F3
F4
3 Move the cursor to "Ref. address"
Manual vane angle
Ref. address
Unit No.
Select the refrigerant address and
Identify unit Check button
the unit number for the units to
Input display:
whose vanes are to be fixed, with
Cur.
Address
Check
the [F2] or [F3] button, and press
the [SELECT] button.
F1
F2
F3
F4
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 4
Press the [F4] button to con rm the
unit.
The vane of only the target indoor
unit is pointing downward.
MITSUBISHI ELECTRIC
LABEL
4 The current vane setting will ap-
Manual vane angle
Select the desired outlets from 1
through 4 with the [F1] or [F2] but-
Select:
ton.
Outlet
Angle
• Outlet: "1", "2", "3", "4" and "1, 2, 3,
F1
F2
F3
F4
Press the [F3] or [F4] button to go
through the option in the order of
"No setting (reset)," "Step 1", "Step
2", "Step 3", "Step 4" and "Step 5".
Select the desired setting.
Manual vane angle
Setting
Main menu (refer to page 7), and
press the [SELECT] button.
the [F1] or [F2] button, and press
the [SELECT] button.
or "Unit No." with the [F1] button
to select.
pear.
4, (all outlets)"
Vane setting
No setting
Step 1
Step 2
Step 3
Step 4
Step 5
All outlets
Press the [SELECT] button to save the settings.
A screen will appear that indicates the setting information is being trans-
mitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 4)
when the transmission is completed.
Make the settings for other outlets, following the same procedures.
If all outlets are selected,
will be displayed the next time
the unit goes into operation.
Navigating through the screens
• To go back to the Main menu ................ [MENU] button
• To return to the previous screen .......... [RETURN] button
Con rmation procedure
Manual vane angle
Ref. address
Unit No.
Identify unit Check button
Input display:
Cur.
Address
Check
F1
F2
F3
F4
Manual vane angle
Ref. address
Unit No.
The air conditioner with the
vane pointing downward is
the target air conditioner.
Input display:
F1
F2
F3
F4
Manual vane angle
There is no response from
the target device.
Confirm the state of the air
conditioner.
Input display:
F1
F2
F3
F4
1 First, con rm by setting "Ref. ad-
dress" to 0 and "Unit No." to 1.
• Move the cursor to "Ref. address"
or "Unit No." with the [F1] button
to select.
• Select the refrigerant address
and the unit number for the units
to whose vanes are to be fixed,
with the [F2] or [F3] button, and
press the [SELECT] button.
• Ref. address: Refrigerant
address
• Unit No.: 1, 2, 3, 4
Press the [F4] button to con rm the
unit.
2 Change the "Unit No." in order
and check each unit.
• Press the [F1] button to select
"Unit No.".
Press the [F2] or [F3] button to
change the "Unit No." to the unit
that you want to check, and then
press the [F4] button.
• After pressing the [F4] button,
wait approximately 15 seconds,
and then check the current state
of the air conditioner.
The vane is pointing
downward.
This air conditioner
is displayed on the remote
controller.
All outlets are closed.
Press the [RETURN] button and
continue the operation from the
beginning.
The messages shown to the
left are displayed.
The target
device does not exist at this
refrigerant address.
• Press the [RETURN] button to
return to the initial screen.
3 Change the "Ref. address" to the
next number.
• Refer to step 1 to change the
"Ref. address" and continue with
the confirmation.
5