Recall the infrared image
5. After startup the camera, press the « menu (enter) » key to pop up the menu;
6. Press the direction key
key to enter
7. Press the direction key
8. Choose your picture with ◄ ► key
To go directly to a specific picture without seeing all the thermograms, press on
and
key.
Items and Functions of the Menu
Sub menu « Analysis »
Analysis
►
File
►
IR / Visible
Manual Adj.
Object Param.
System Setup ►
Cancel the analysis
Sub menu « File »
Analysis
►
File
►
IR / Visible
Manual Adj.
Object Param.
System Setup ►
If a voice remark is associated with an image, you
can listen to it on the camera. (bluetooth option)
Sub menu « IR / Visible »
Analysis
►
File
►
IR / Visible
Manual Adj.
Object Param.
System Setup ►
and
and
Analysis
File
IR / Visible
Manual Adj.
Object Param.
System Setup►
The camera will come into the temperature measurement
condition. Move the camera or move the direction key to
point the cursor to the target, the target's temperature
Spot1
value will be displaying on the right-up of the screen
Spot2
Maximal or minimal temperature: one spot is tracking the
Spot3
highest or lowest temperature in the area.. The user can
<Maximum>
change the size of the area.
Isotherm
The camera will do the isotherm analysis of the infrared
Profile
image. If the temperature is in one setting area, it will be
Area
displayed in one color.
>
<Remove all
Display of the temperature distribution on a line
The camera will do the analysis of minimum, maximum,
average on an area.
tools
Open
Save
Delete
File setup ►
Voice rec.
Voice Play
IR / Vision
IR Percent
English
to enter « FILE », then press the "menu"
to "Open" and press "ENTER"
►
►
Open the images of the Flash Disk
Save the image to the Flash Disk
Delete the images of the Flash Disk
Display of the data stored and selection of the
directory name.
You can associate up to 30 seconds of voice
remarks with an image (bluetooth option)
I.R.: only the I.R. image is displayed on
screen. All of the analysis tools are available.
VISION: only the visual image is displayed on
screen. The analysis tools are not all available
MIXVISION: the visual image appears in the
background and the central window is the
fusion zone. You can apply all of the analysis
tools to this zone.
Percentage of thermal image in the display
(100% : pure I.R. image, 0% : real image only).
11