Descargar Imprimir esta página

Outsunny 845-489V90 Manual Del Usuario página 13

Publicidad

Idiomas disponibles

Idiomas disponibles

Screwdriver
Rotate blade 180 °
When both cutting edges of the blade have become worn they must be replaced as a pair.
The blades can be re-sharpened, but this must be done by an experienced person using an
oil stone. We do not recommend this be done as the weight of each blade is critical to
maintain the balance of the cutting disc. Any imbalance could cause damage to the
machine and possible injury to the operator.
How do I maintain this product?
1. Wa r n i n g : D u r i n g m a i n t e n a n c e a n d c l e a n i n g e n s u r e t h e m a c h i n e i s
disconnected from the mains.
2. When the appliance is stopped for servicing, inspection, or storage, or to
change an accessory, switch off and pull the plug from the mains supply before
making any inspections, adjustments, etc.
3. If an extension cord is used it shall not be of lighter grade than the supply cord
already fitted to the appliance.
4. Check the supply and any extension cord regularly for damage or signs of
ageing. Do not use the appliance, if the cords are damaged.
5. When servicing the cutting means be aware that, even though the motor will not
start due to the interlock feature of the guard, the cutting means can still be
moved if the motor is turned by hand.
6. Never attempt to override the interlock feature of the guarding.
7. Remove deposited matter from the machine using a brush.
8. Always clean the machine after use. Clean the plastic body and plastic parts
using soap and a moist cloth. Do not use aggressive agents or solvents for
cleaning.
9. Never clean the shredder with a jet of water or by rinsing. Make sure that no
water is allowed to enter into the shredder.
10.
Use only the recommended accessories and attachment for this shredder.
NOTE:For
Model: HY6601H, HY6602J, HY6603L
Determine the maximum permissible system impedance Zmax(0.324Ω) at the
interface point of the user's supply ,declare Zmax(0.324Ω) in the equipment
instruction manual and instruct the user to determine in consultation with the
supply authority, if necessary, that the equipment is connected only to a supply of
that impedance or less.
NOTE:For
Model: HY6604H, HY6605J, HY6606L
The equipment is intended for use only in premises having a service current
capacity ≥100A per phase, supplied from a distribution network having a nominal
voltage of 230V, and instruct the user to determine in consultation with the supply
authority, if necessary, that the service current capacity at the interface point is
sufficient for the equipment.
The equipment shall be clearly marked as being suitable for use only in premises
having a service current capacity equal to or greater than 100 A per phase.
Remove 2 hex
headed screws
Hex spanner
12
EN
Fig. 9

Publicidad