CONFIGURATION MENU
When you have dispensed the target amount into the
calibrated container, release the trigger to stop the
fluid supply.
4. Press the CANCEL button and you will be asked if you
wish to cancel to finish dispensing. If we have finished
we will confirm by pressing the ENTER button. If, on the
contrary, we want to continue dispensing, we will press
the CANCEL button.
CALIB.
2.05
CANCEL?
5. The dispensed quantity is displayed and after 5 seconds
the message "QTE REAL?" is shown on the display.
CALIB.
2.05
QTE REAL?
6. Once this amount has been set, press the ENTER button
to confirm and the gun automatically displays the
newly calculated calibration factor:
CALIB.
FACTOR K
1025
Alentec & Orion AB Grustagsvägen 4, SE-13840, Älta, SWEDEN · info@alentec.se · www.alentec.com
001
We must indicate the quantity actually dispensed, which will
be the quantity registered by the calibrated container. The
UP/DOWN buttons are used to modify the digit value and
the LEFT/RIGHT arrows are used to change the digit.
001
001
CALIB.
2.05
CALIB.
2.05
CANCELLED
CALIB.
2.00
QTE REAL?
R. 05/23 105 277
EN
001
4.00 L
001
001
11