POSITIONING OF OUTLET
TERMINALS
The outlet terminals for forced draught
systems may be located on the outer walls
of the building Table 3 shows approximate,
non-binding minimum distances to be met
for a building of the type shown in fig. 13.
2. 1 2
CONNECTION TO
ELECTRICITY SUPPLY
For the electricity supply, which must have
TABLE 3
Siting of terminal
A - below openable window
B - below ventilation opening
C - below eaves
D - below balcony (1)
E - from adjacent window
F - from adjacent ventilation opening
G - from horizontal or vertical soil or drain pipes (2)
H - from corner of building
I - from recess in building
L - from ground level or other treadable surface
M - between two terminals set vertically
N - between two terminals set horizontally
O - from a surface facing without
openings or terminals
P - as above but with openings and terminals
1) Terminals below a practicable balcony must be located in such a way that the total path of the smoke from its outlet point
from the terminal to its outlet point from the external perimeter of the balcony, including the height of possible railings, is
not less than 2000 mm.
2) When siting terminals, where materials that may be subject to the action of the combustion products are present in
the vicinity, e.g., eaves, gutters and downspouts painted or made of plastic material, projecting timberwork, etc., distan-
ces of not less than 1500 mm must be adopted, unless adequate shielding is provided to guard these materials.
6
70
single phase voltage of 230V-50Hz, connect
the three-pole wire supplied with the boiler
to a mains switch protected with fuses, with
a distance between contacts of at least 3
mm.
In the case of replacement, the said wire
must be requested from SIME.
NOTE: The appliance must be connected
to an efficient earth system.
SIME declines all responsibility for dama-
ges to persons or property deriving from a
non-earthed boiler.
Appliances from 7 to 35 kW
(distances in mm)
600
600
300
300
400
600
300
300
300
2500
1500
1000
2000
3000
7
5
4
3
2. 1 2. 1 Electrical panel (fig. 9)
For access to the panel, switch off the elec-
tricity and unscrew the screws fixing the
cover to the box containing the connections.
The panel can be made to slope downwards
by removing the two lower screws that hold
it to the frame.
1
2
KEY
1
12 clamp terminal board
2
Voltage presence green LED
3
11-pole wired connector code 6299931
4
Circuit board code 6301401
5
5-pole wired connector code 6299932
6
14-pole wired connector code 6299934
7
6-pole wired connector code 6299933
Fig. 13
Fig. 14