Descargar Imprimir esta página

HIKOKI RP 250YBL Instrucciones De Manejo página 7

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
Hold the fleece filter bag on the flange and, with its
opening, guide it first over the latch at the bottom
part of the suction opening, then fit up to the stop on
the suction opening. Replace the upper part of the
device on the container, close the snap locks.
9. The device
9.1
Switching On/Off, Automatic, vibrator
Select operating mode at switch (1):
0= Dust extractor off
I = Dust extractor on (manual operation)
A=Automatic On/Off switch:
The dust extractor is switched on or off by
means of a power tool connected to the plug
socket (3).
R A= Automatic On/Off switch and
Automatic vibrator switch
• If the switch (1) is turned to position R A, the
electromagnetic vibrator switches on. Dust is
then shaken off the filter. The vibrator
switches off automatically after approx. 10 s.
• In switch position R A, the dust extractor is
switched on or off by means of a power tool
connected to the plug socket (3).
• In switch position R A, the electronic system
checks the air flow during work. If the flow is
too low due to a contaminated filter, the
volume flow control display lights up (2).
During the next work break of the connected
power tool, the electronics system switches
the vibrator off for approx. 10 s.
9.2
Plug socket (3)
The plug socket (3) is designed for connection
to a power tool only.
The total maximum permissible current
consumption (of dust extractor and connected
unit) must not exceed 16 A.
CAUTION! Ensure that the power tool is
switched off when plugging it in. Regardless of
the switch position, the plug socket is always live
when the mains plug is plugged in.
If the switch (1) is in the "0" position, you can use the
plug socket as an extension lead (e.g. for a light
fitting).
If the switch (1) is in the "RA" position, the dust
extractor is switched on or off by means of a power
tool connected to the plug socket (3).
9.3
Volume flow control display
The volume flow control display (2) lights up when
the container is full and/or if the suction hose is
blocked.
10. Use
10.1 Dry Vacuuming
Vacuum using a dry filter, dry device and dry acces-
sories only. If the cartridge is damp, dust may stick
and form a crust.
Always use filter cassettes (13) when using fleece
filter bags (4).
10.2 Wet vacuuming
Never operate the device without inserting
filter cassettes (13) first. The device may be
destroyed and water may also escape.
You can use fleece filter bags (4). The filter
cassettes (13) are suitable for wet vacuuming.
Before carrying out any wet vacuuming, remove the
dry vacuumed material. This process will prevent
severe soiling and encrustation.
The integrated water sensor switches off the motor
when the container is full. Empty the device. If the
device is not switched off, the restart protection
device remains effective. The device is not oper-
able again until it has been switched off and
switched back on again.
After switching off, some water may run back out of
the hose.
Before emptying, first of all take the suction hose out
of the liquid.
If you are then going to dry vacuum, insert a dry
filter. If there is frequent switching between dry and
wet vacuuming, we recommend the use of a second
(replacement) filter. Allow the filter, container and
accessories to dry: otherwise dust may adhere to
damp components.
10.3 Transport
Leave the hose on the device to prevent dust acci-
dentally escaping.
Place the accessories in a suitable plastic bag and
seal the bag.
Suspend the mains connection lead on the cable
holder (5).
The upper part (6) must be securely sealed to the
container (8) - check that the snap locks (7) are
closed.
11. Cleaning
11.1 General Cleaning Instructions
Clean the container and accessories with water.
Wipe the upper part (6) with a damp cloth.
CAUTION! This device contains dust that is harmful
to health. Discharge and maintenance operations
(including disposal of the dust collection containers)
must only be carried out by qualified specialists
wearing appropriate protective clothing and equip-
ment.
Emptying the Container
Only permitted for dusts with
occupational exposure limits > 1 mg/m
- Unplug mains cable.
- Open the snap locks (7). Remove the upper part
(6) from the container (8).
Dispose of the fleece filter bag.
- Unplug mains cable.
- Pull on mask.
- Open the snap locks (7). Remove the upper part
(6) from the container (8).
English
3
.
7

Publicidad

loading