It is
stronqlv recommended
that this appliance be installed
in conjunction with a suitable overhead
vent hood (see
"Step f: Ventilation Requirements"
on page 3). Due to the
high heat capability of this unit, particular attention should
be paid to the hood and duct work installation to assure it
meets local building codes.
This appliance has been tested in accordance with ANSI
Z21.1, Standard for Household Cooking Appliances (USA)
and in accordance with CAN 1.1-M81 Domestic Gas
Ranges (Canadian).
This appliance complies with one or more of the following
standards:
UL 858, Standard for the Safety of Household Electric
Ranges
UL 923, Standard for the Safety of Microwave Cooking
Appliances
UL 507, Standard for the Safety of Electric Fans
ANSI Z21.1, American National Standard for
Household Cooking Gas Appliances
CAN/CSA-C22.2
No. 113-10 Fans and Ventilators
CAN/CSA-C22.2
No. 61-08 Household Cooking
Ranges
It is the responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific installations.
(2) 1/2" wrenches
1/8" (3.17mm) drill bit
3/16" (4.76mm)drill
bit
12" Adjustable wrench
Hand or electric drill
Tape measure
Phillips & flathead screwdrivers
Marking instrument
Level
Furniture dolly
T-20 Torx screwdriver
Protective gloves
Items Not Included
Drywall/Concrete
Anchors
Pipe Compound/Tape
Rope/Twine
3/4" (19mm) Flex Line
(2) NPT Flare Adapters
Step 1: Ventilation
Requirements
It is stronqlv recommended that a suitable exhaust hood be
installed above the range. Downdraft ventilation should not
be used. The table below indicates the ventilation hood
options and blower capacity guidelines that are
recommended for use with all THERMADOR ® ranges.
Do not install a microwave oven/ventilator
combination
above the range as these type of units do not provide the
proper ventilation and are not suitable for use with the
range.
IMPORTANT:
Ventilation hoods and blowers are designed for use with
single wall ducting. However, some local building codes or
inspectors may require double wall ducting. Consult local
building codes and/or local agencies before starting to
assure that hood and duct installation will meet local
requirements.
NOTICE:
Most range hoods contain combustible components which
must be considered when planning the installation.
,
,
,
Select Hood and Blower Models:
For wall installations, the hood width must, at a
minimum, equal the width of the range. Where space
permits, a hood larger in width than the range may be
desirable for improved ventilation performance.
For island installations, the hood width should
overhang the range by a minimum of 3" (76mm) on
each side.
Hood Placement:
For best smoke elimination, the lower edge of the hood
should be installed 30" (762mm) above the range
cooking surface. Use a 36" (914mm) minimum
clearance if the hood contains any combustible
materials such as a wood covering (Figure 1 on
page 5).
Consider
Make-Up Air:
Due to the high volume of ventilation air, a source of
outside replacement air is recommended. This is
particularly important for tightly sealed and insulated
homes.
A qualified heating and ventilating contractor should be
consulted.
English 3