Motor
This motor has a manual thermal
overload protector. If the motor
overheats for any reason, the
overload protector
will shut off the
motor. The motor must be allowed to
cool down before restarting.
To
restart:
1.
Place the On/Auto/Off
lever in
the Off postion.
2.
Allow the motor to cool.
3.
Depress the red reset button on
the motor.
4.
Place the On/Auto/Off
lever in
the On/Auto postion to restart
the motor.
Pressure
Switch
- Replacement
Risk of Bursting.
Pressure loads
beyond design limits may cause
tank rupture or explosion. Pressure
switch operation is related to
motor HP, tank rating, and safety
valve setting. Do not attempt
to
adjust, remove, or defeat the
pressure switch, or change and
modify any pressure control related
device. If replacement
is necessary
the same rated switch must be
used. Contact a trained service
technician for replacement.
To Replace
Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug air compressor.
3.
Remove the regulator ring and
remove the console cover.
4.
Using an adjustable wrench
loosen pressure relief tube nut at
air tank and pressure switch.
5.
Lift retaining clip from handle and
remove handle.
6.
Retaining clip
Using an adjustable wrench,
rotate the pressure switch
assembly as shown.
Tank
7.
Remove the outlet pressure
8.
9.
gauge, tank pressure gauge, and
quick connect (if equipped) from
the regulator.
Remove the regulator.
Apply pipe sealant tape to the
nipple.
21_ENG
D30090