1. GENERAL DESCRIPTION
ACG9062 is a slim-line proximity reader that operates a miniature solid-state relay upon recognition of a correctly enabled card or tag. The unit's relay output can either by
momentary (pulsed) or toggle (bi-stable).
The unit is designed for both internal and external use (IP 67). The resin filled interior makes it completely submersible in water and/or resistant to tamper. A total of 200 different
cards or tags can be programmed into the ACG9062.
2. TECHNICAL CHARACTERISTICS - CONNECTIONS
Power supply
12 VDC
Consumption
30 mA
Reading technology
proximity, 125 kHz
Range
4 cm
Memory capacity
200 users
No. of output relays
1 - pulsed (1 sec) or bi-stable. Selectable
Relay contact rating
2 A @ 60 VDC
Safety devices
Interior completely filled with resin, magnetic tamper
Indicators
two-colour LED (Red/Green), buzzer
Protection class
I.P. 67
Dimensions/weight
28 x 92 x 12, 165 g
Working temperature
from -20°C to +55°C
3. OPERATION
The programming operations that can be performed on ACG9062 are:
- programming a single tag
- disabling a single tag
- disabling all tags
The built-in two-colour red/green LED and the buzzer provide all the indications necessary to identify the current programming phase and relay status.
PAY ATTENTION: the first tag that will be stored into the proximity reader, becomes the TAG MASTER. Keep it aside as it'll be useful for future tag storing and/or erasing.
Programming a single tag
If no tags are present in memory:
1. Hold a tag in front of the ACG9062 for at least 6 seconds and remove it as soon as the led turns to green.
2. Present the tags to be entered in front of the ACG9062. At each entry, the green LED flashes.
3. Wait 10 seconds until the LED becomes red again.
If tags are already present in memory:
1. Hold an already programmed tag in front of the ACG9062 for at least 6 seconds and remove it as soon as the led turns to green.
2. Present the tags to be entered in front of the ACG9062. At each entry, the green LED flashes.
3. Wait 10 seconds until the LED becomes steady red again.
Disabling a single tag
1. Hold an already programmed tag in front of the ACG9062 for at least 10 seconds and remove it as soon as the led starts flashing red.
2. Present the tags to be disabled in front of the ACG9062. At each entry, the LED flashes red at a higher frequency.
3. Wait 10 seconds until the LED becomes steady red again.
Disabling all tags
Take extreme care when carrying out the following operation. It will cancel all data from the memory.
Once the cancellation procedure has been carried out, the programming cannot be recovered.
For better security, only the tag which was first programmed in the ACG9062 is able to perform this operation
WARNING: if the first tag is misplaced, it will no longer be possible to totally delete the memory.
1. Hold the tag which was first programmed in front of the ACG9062 for at least 10 seconds and remove it as soon as the led starts flashing red.
2. Present the same tag for at least 3 seconds and remove it as soon as the led starts flashing at a higher frequency.
3. MEMORY IS NOW ERASED and the LED becomes steady red again.
4. LED DRIVING
If the ORANGE and CYAN wires are left unconnected or tied to 5VDC the status of the led is driven by the reader itself.
If one or both of the ORANGE and CYAN wires are connected to GROUND, the status of the LED changes as follows:
ORANGE wire
CYAN wire
GROUND
GROUND
GROUND
5VDC or floating
5VDC or floating
GROUND
5. RELAY OPERATING MODE
If the YELLOW wire is left unconnected or tied to 5VDC, the contact type is N.O.
If the YELLOW wire is tied to GROUND, the contact type is N.C.
If the BROWN wire is left unconnected or tied to 5VDC the relay mode is pulsed (1 second)
If the BROWN wire is tied to GROUND, the relay mode is toggle/bi-stable.
6. TAMPER SWITCH
ACG9062 is equipped with an internal REED switch, which is activated by the magnet given as issued. The switch may be used as anti-tampering.
DECLARATION OF CONFORMITY
RIB declares that the following equipment PROXIMITY READER ACG9062 IS IN ACCORDANCE with the 99/05/EC (R&TTE) directive.
Colour
Red
Black
Green
White
Yellow
Brown
Orange
Cyan
Rose
Violet
LED status
OFF
RED
GREEN
Function
12 VDC
GROUND
Relay contact
Relay contact
Relay contact type
Relay mode
Red LED driving
Green LED driving
TAMPER
TAMPER
G
B