Dometic COOLFREEZE CF 18 Instrucciones De Uso página 25

Nevera por compresor
Ocultar thumbs Ver también para COOLFREEZE CF 18:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CF18, CF25, CF35, CF40, CF50
10
Troubleshooting
Fault
Device does not
function, LED does
not glow.
The device does not
cool (plug is inserted,
"POWER" LED is lit).
The device does not
cool (plug is inserted,
"POWER" LED flashes
orange, display is
switched off).
When operating from
the DC outlet:
The ignition is on
and the device is not
working and the LED
is not lit.
EN
Possible cause
No voltage was
detected in the DC
power outlet.
No voltage present in
the AC voltage outlet.
The device fuse is
defective.
The integrated power
supply adapter is
defective.
Defective compressor.
Battery monitor is set
too high.
Battery voltage is too
low.
The DC outlet is dirty.
This results in a poor
electrical contact.
The fuse of the DC plug
has blown.
The vehicle fuse has
blown.
Suggested remedy
In most vehicles the ignition must be
turned on before power will be supplied
to the DC power outlet.
Try using another plug outlet.
Replace the device fuse, see chapter
"Replacing the AC fuse (CF35, CF40,
CF50)" on page 22.
This can only be repaired by an
authorized repair center.
This can only be repaired by an
authorized repair center.
Select a lower battery monitor setting.
Test the battery and charge it as needed.
If the plug of your cooler becomes very
warm in the DC outlet, either the DC
outlet must be cleaned or the plug has
not been assembled correctly.
Replace the fuse in the DC plug, see
chapter "Replacing the DC plug fuse" on
page 23.
Replace the vehicle's DC outlet fuse.
Please refer to your vehicle's operating
manual.
Troubleshooting
25

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Coolfreeze cf 25Coolfreeze cf 35Coolfreeze cf 40Coolfreeze cf 50Cf 18Cf 25 ... Mostrar todo

Tabla de contenido