Installation
3 Connect the cable to the CN10.
a. This motion sensor can be installed to any four corners
of the air panel. In the case of installing it to far corner
from the electrical box, run through the wiring for the
motion sensor kit on the fixing plate of the unit between
the motion sensor kit and the electrical box of the unit as
shown.
After running the connecting cable, clamp the extra
length of the connecting cable by the plastic band and
store it at inside the ceiling.
?
N O T E
If installing the motion sensor kit near the electrical box, an extra
cable shall bind up by the wire clamp.
b. pen the electrical box cover at the indoor unit. Connect the connecting cable to CN10 of PCB in the electrical box.
4 After the installation work for the motion sensor kit is completed, attach the corner pocket covers (3 portions). The detail should
be referred to the installation manual of the air panel.
?
N O T E
After the motion sensor kit is attached to the air panel, the one corner pocket cover (It was attached with air panel.) becomes unnecessary.
4
PMML0368A rev.0 - 06/2015 - P5415640
CN10
Example: Installing motion sensor Kit to for corner from
electrical box
Indoor unit wiring
connection
CN10
Indoor unit
Electrical box
ON
1 2
Wire clamp
Connecting cable
Fixing
plate
Wire clamp
Cable
Air panel