Descargar Imprimir esta página

Mitsubishi Electric TPCA0A 1KA70 Serie Manual De Instalación página 8

Ocultar thumbs Ver también para TPCA0A 1KA70 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

6. Electrical work
14
Service menu
Test run
Input maintenance info.
Settings
Check
Others
Main menu: RETURN
Cursor
Fig. 6-5
Function setting
Ref. address
Unit No.
Grp./1/2/3/4/All
Monitor: SELECT
Cursor
Address
F1
F2
F3
F4
RETURN SELECT
MENU
HOLD
Fig. 6-7
Function setting
Ref. address
Grp.
Mode 1
Mode 2
Mode 3
Mode 4
Request: SELECT
Cursor
Cursor
F1
F2
F3
F4
RETURN SELECT
MENU
HOLD
Fig. 6-9
en
7
A
MODEL SELECT
ON/OFF
TEMP
3
FAN
AUTO STOP
MODE
VANE
AUTO START
CHECK
LOUVER
h
TEST RUN
min
2
SET
RESET
CLOCK
Fig. 6-4
Settings menu
Function setting
Service menu: MENU
F1
F2
F3
RETURN SELECT
MENU
HOLD
Fig. 6-6
Function setting
Ref. address
Grp.
Mode 1
Mode 2
Mode 3
Mode 4
Cursor
Cursor
F1
F2
F3
ON
RETURN SELECT
MENU
OFF
HOLD
Fig. 6-8
Function setting
Ref. address
Grp.
Sending data
F1
F2
F3
ON
RETURN SELECT
MENU
OFF
HOLD
Fig. 6-10
4) IR wireless remote controller pair number setting operation (Fig. 6-4)
1 Press the SET button with something sharp at the end.
Start this operation from the status of IR wireless remote controller display turned
off.
blinks and Model No. is lighted.
MODEL SELECT
min
2 Press the
button twice continuously. Pair No. "0" blinks.
3 Press the temp
If you mistook the operation, press the ON/OFF
from procedure 2.
4 Press the SET button with something sharp at the end.
Set pair number is lighted for 3 seconds then turned off.
A Pair No. of IR wireless remote controller
6.3. Function settings
6.3.1. Function setting on the unit (Selecting the unit functions)
1) For wired remote controller
1 (Fig. 6-5)
• Select "Service" from the Main menu, and press the [SELECT/HOLD] button.
• Select "Settings" from the Service menu, and press the [SELECT/HOLD] button.
2 (Fig. 6-6)
• Select "Function settings" with the [SELECT/HOLD] button.
F4
3 (Fig. 6-7)
ON
• Set the indoor unit refrigerant addresses and unit numbers with the [F1] through
OFF
[F4] buttons, and then press the [SELECT/HOLD] button to confirm the current
setting.
<Checking the Indoor unit No.>
When the [SELECT/HOLD] button is pressed, the target indoor unit will start fan
operation. If the unit is common or when running all units, all indoor units for the
selected refrigerant address will start fan operation.
4 (Fig. 6-8)
• When data collection from the indoor units is completed, the current settings
appears highlighted. Non-highlighted items indicate that no function settings are
made. Screen appearance varies depending on the "Unit No." setting.
F4
5 (Fig. 6-9)
• Use the [F1] or [F2] button to move the cursor to select the mode number, and
ON
change the setting number with the [F3] or [F4] button.
OFF
6 (Fig. 6-10)
• When the settings are completed, press the [SELECT/HOLD] button to send the
setting data from the remote controller to the indoor units.
• When the transmission is successfully completed, the screen will return to the
Function setting screen.
F4
ON
OFF
buttons to set the pair number you want to set.
button and operate again
Indoor PC board
0
Initial setting
1
Cut J41
2
Cut J42
3-9
Cut J41, J42

Publicidad

loading

Este manual también es adecuado para:

Tpca0a024 1ka70Tpca0a030 1ka70Tpca0a036 1ka70Tpca0a042 1ka70