Descargar Imprimir esta página

EINHELL CLEANEXXO Manual De Instrucciones Original página 17

Fregadora de suelos inalámbrica

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 92
sensory or mental capacities or those with a lack
of experience and knowledge.
4. Technical data
Motor power supply: ...................................... 18V
Capacity of the fresh water tank: ...............400 ml
Capacity of the dirty water tank: ................300 ml
Weight: ...................................................... 2,5 kg
Important!
The equipment is supplied without batteries and
without a charger and is allowed to be used only
with the lithium-ion batteries of the Power X-
Change series!
The lithium-ion batteries of the Power X-Change
series are allowed to be charged only with Power
X-Chargers.
Suitable batteries and chargers from the Power
X-Change series are for example.
Battery: Power X-Change 1.5
Battery: Power X-Change 5.2
Charger: Power X-Charger 3A
Charger: Power X-Charger
Danger!
Sound and vibration
The sound and vibration values were measured in
accordance with EN 60335-2-10.
Sound pressure level L
Uncertainty K
............................................. 3 dB
pA
Sound power level L
WA
Uncertainty K
............................................. 3 dB
WA
5. Before putting into operation
Caution!
Protect your battery pack against moisture,
rain and high humidity. Make sure that no water
runs over the battery pack or its contacts during
operation.
Warning!
Always pull out the battery before making
any settings on the equipment.
Anl_CLEANEXXO_SPK13.indb 17
Anl_CLEANEXXO_SPK13.indb 17
..................... 62.6 dB(A)
pA
......................... 74.1 dB(A)
GB
5.1 Using the equipment correctly
The tool must be stood on a level, stable
surface.
So that the pump does not suffer any damage
when it is not in use, a small amount of leaka-
ge from the pump is normal.
Never use the machine in potentially explosi-
ve areas under any circumstances!
The operating temperature must be between
+5 and + 40°C.
The tool is designed to be used with cold or
lukewarm water (max. 40°C); higher tempera-
tures will result in damage to the pump.
Do not use water that is dirty, gritty or con-
tains any chemical products, as these could
impair operation and shorten the life of the
equipment.
The tool is approved for use only with pure
tap water and standard, commercially availa-
ble floor cleaning agent.
When using cleaning agents, refer to the
instructions for use, safety information etc.
provided by the manufacturer.
Warning – Risk of explosion
Do not spray fl ammable liquids.
Warning
If cleaning agent gets into contact with your skin
or into your eye, rinse immediately with lots of
clean water. Then consult a doctor or follow the
steps described on the safety data sheet or provi-
ded by the manufacturer of the cleaning agent.
5.2 Assembly
5.2.1 Assembling the tool (Fig. 11)
Push the parts of the tool together and make sure
that the two locking clips (17) engage securely in
the housing.
Note: Check that the attachment is securely sea-
ted before you start cleaning.
5.2.2 Inserting the battery (Fig. 6)
To insert the battery in the battery holder (15),
press the locking button for the battery holder
(14) so that the battery holder (15) folds open.
Then insert your battery in the device and fold the
battery holder back into the device.