PRODUCT DESCRIPTION
4.2 INSTALLATION
• Connect the Hi-Box to the ADSL box. Connect the RJ45
cable, factory supplied, to the Ethernet port, indicated with
the logo
• Connect the power pack provided to the connector indicated
by the logo
• This product is completely switched off when disconnecting
the power supply plug.
5 PRODUCT DESCRIPTION
Rear Side
Status indicator
6 TECHNICAL DATA
Technical data
• Dimensions (mm): 110 x 71.25 x 28.13
• ABS-PC plastic housing
• Pollution category: Class 2
• Operating Temperature: +5°C to + 35°C
• Operating Humidity: between 30% and 80%
• Equipment protection rating: IP30
• Maximum altitude for use: < 2000m
Communication
• Radio frequencies 868.25MHz, 868.95MHz and 869.85MHz,
in compliance with the standard.
7 PAIRING THE HI-BOX TO ATW-TAG-02 AND/OR SPX-TAG01
The "ATW-TAG-02" and "SPX-TAG01" "Prog" button allows to
reset the radio configuration and sets the product in pairing
mode. The "Prog" indicator allows to find out the status of the
radio configuration of the product.
Actions and Status on ATW-TAG-02 and SPX-TAG01
Pressing the "Prog" button >3 sec pressure it opens the radio
pairing mode.
When Status indicator Flashes, device is in pairing mode.
When Status indicator is OFF, the interface is paired with the
Hi-Box.
?
N O T E
After releasing "Prog" button, the Status indicator flashes until pairing is
complete (up to 8 minutes). Pairing launching is done through Gateway
and App.
2
PMML0370A REV.0 - 06/2016
PROG Button
RJ45 Ethernet connector
RESET button
Power supply connector
?
N O T E
The status indicator displays the operating mode of the Hi-Box device.
!
C A U T I O N
•
The Ethernet interface must never be directly connected to a
telephone socket.
•
Connect the Hi-Box to your ADSL box or to any other Switch or
Ethernet Hub type network equipment.
?
N O T E
•
Place the Hi-Box at least 30 cm from the Internet modem.
•
Do not set the Hi-Box device on a metal surface.
LED
Green
Device is ready and connected to the server
No transmission. RJ45 cable disconnected.
Red
Transmission failure
Orange Initializing
Power supply
• Supply voltage: 230V/50Hz
• Continuous 5V/0.5A power supply.
• Consumption in normal operation: Continuous 5V/120mA
Declaration of conformity