CARE AND CLEANING (Continued)
5. Attach the grille (B) by pinching the mounting springs and
inserting them into the narrow rectangular slots in the fan
housing (A).
Turn on power source.
TROUBLESHOOTING
PROBLEM
The fan seems louder than
it should be.
The fan is not clearing
humidity from the room.
LIMITED 5-YEAR WARRANTY
If this product fails due to a defect in materials or workmanship at any time during the first FIVE years of ownership, the
manufacturer will replace it free of charge, postage-paid at their option. This warranty does not cover products that have
been abused, altered, damaged, misused, cut or worn. This warranty does not cover use in commercial applications. Use
only manufacturer-supplied genuine warranty repair replacement parts to repair this fan. Use of non-genuine repair parts
will void your warranty. The manufacturer DISCLAIMS all other implied or express warranties including all warranties of
merchantability and/or fitness for a particular purpose. As some states do not allow exclusions or limitations on an implied
warranty, the above exclusions and limitations may not apply. This warranty gives you specific legal rights, and you may
have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation,
repair, replacement as well as incidental and consequential damages connected with the above are excluded. Any damage
to this product as a result of neglect, misuse, accident, improper installation or use other than the purpose SHALL VOID
THIS WARRANTY.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.
Inquiries regarding warranty claims can be directed to 1-866-994-4148, 8 a.m. - 8 p.m., EST, Monday - Sunday. You could also
contact us at partsplus@lowes.com.
POSSIBLE CAUSE
The CFM is too great.
The damper is damaged or not working
properly.
The bend in the duct is too close to the
fan discharge.
The fan discharge is reduced to fit a smaller
duct.
The fan body is not attached securely.
There is insufficient airflow intake in the room.
There is insufficient CFM.
NOTE: Using a tissue is not the correct
method for determining if the fan is operating
properly. If the fan clears steam from the
room within approximately 15 minutes of
completing your shower, then the fan is
operating properly.
5
Mounting
springs
Be sure the CFM rating on the fan matches the square
footage of your room.
Check the damper to ensure it is opening and closing
properly. If the damper has become damaged, please
call Customer Service.
Be sure you do not have any sharp bends in the duct
within 18 in. of the fan discharge.
Use the recommended size ducting to reduce fan noise.
Be sure the fan is securely attached to the ceiling joists.
Be sure a door or window is slightly ajar or open to allow
airflow. The fan is not able to draw air out of the room
without enough airflow.
Be sure the CFM rating on the fan matches the square
footage of your room.