INSTALLATION MANUAL
20
7.1. TABLE A OPTIONAL SETTING ITEMS
Individual
No. Items Optional Function
Removal of Heating
1
b1
Temperature
Compensation
Circulator Function
2
b2
at Heating Thermo-
OFF
3 Minutes OFF
3
b3
Guard Compressor
4
b4
Period for Filter Sign
Fixing of Operation
5
b5
Mode
Fixing of Setting
6
b6
Temperature
Fixing Cooling
7
b7
Operation
Automatic COOL/
8
b8
HEAT Operation
9
b9
Fixing Fan Speed
10
bA
Not Prepared
Cooling Temperature
11
bb
Compensation
12
bC
Not Prepared
13
bd
Not Prepared
14
bE
Not Prepared
15
C1
Not Prepared
16
C2
Not Prepared
17
C3
Not Prepared
18
C4
Not Prepared
Increasing Fan
19
C5
Speed
Increasing Fan
20
C6
Speed
Canceling 3 Minutes
21
C7
Compressor Guard.
Thermistor of
22
C8
Remote Control
Switch
23
C9
Not Prepared
24
CA
Not Prepared
Selection of Forced
25
Cb
Stoppage Logic
26
CC
Not Prepared
27
Cd
Not Prepared
28
CE
Not Prepared
Change of Louver
29
CF
Swing Angle
Power Supply
30
d1
ON/OFF 1
31
d2
Not Prepared
Power Supply
32
d3
ON/OFF 2
Prevention for
33
d4
Cooling Discharge
Air Temp. Decrease
Prevention for
34
d5
Heating Discharge
Air Temp. Decrease
Room Temp. Control
35
d6
for Energy Saving
NOTES:
*1: The "02" setting may not be available according to the type of indoor unit.
*2: In case of RPI models, 00: Increasing fan speed 1 (standard),
01: Increasing fan speed 2 (high static pressure), 02: Standard
(low static pressure)
*3: 00: Standard (7-step operation), 01: Draft Prevention (lower 2 steps
cutoff), 02: High ceiling (upper 2 steps cut off)
*4: Applicable to fan, cooling and dry operation modes.
*5: Applicable to heating operation mode.
Setting
Contents
Setting
Condition
Standard (Set Temp.
00
+4ºC)
01
Removal (Set Temp.)
02
Set Temp. +2ºC (*1)
00
Not Available
01
Available
00
Not Available
01
Available
00
Standard
01
100 hours
02
1,200 hours
03
2,500 hours
04
No Indication
00
Not Available
×
01
Available
00
Not Available
×
01
Available
00
Not Available
×
01
Available
00
Not Available
×
01
Available
00
Not Available
×
01
Available
×
"- -" Fixed
Not Used
Standard (No
00
Compensation)
01
Set Temp. –1ºC
02
Set Temp. –2ºC
00
Not Used
-
01
(Use as 00 conditions)
00
Not Used
-
01
(Use as 00 conditions)
00
Not Used
-
01
(Use as 00 conditions)
00
Not Used
-
01
(Use as 00 conditions)
-
"- -" Fixed
Not Used
00
Not Used
01
(Use as 00 conditions)
00
Not Used
01
(Use as 00 conditions)
00
Not Available
01
Hi Speed 1 (*2)
02
Hi Speed 2 (*2)
00
Not Available
01
Available
00
Available
01
Not Available
00
Not Available
01
Control by Indoor
Suction Thermistor
02
Control by Thermistor
of Remote Control
Switch Control by
Average Value of Indoor
Suction Thermistor and
Thermistor of Remote
Control Switch
-
"- -" Fixed
Not Used
-
"- -" Fixed
Not Used
00
Forced Stoppage Input:
A Contact
×
01
Forced Stoppage Input:
B Contact
00
Not Used
×
01
(Use as 00 conditions)
00
Not Used
01
(Use as 00 conditions)
00
Not Used
-
01
(Use as 00 conditions)
Standard (7 Steps)
00
Draft Prevention
01
(5 Steps) High Ceiling
02
(5 Steps) (*3)
00
Not Available
01
Available
-
"- -" Fixed
Not Used
00
Not Available
01
Available
00
Not Available
01
Available
00
Not Available
01
Available
00
Not Available
01
Available
Individual
No. Items Optional Function
Setting
36
d7
Not Prepared
37
E1
Ventilation Mode
Increasing Supply
38
E2
Air Volume
39
E3
Not Prepared
Precooling /
40
E4
Preheating Period
41
E5
Not Prepared
Indoor Fan
Operation Time After
42
E6
Cooling Operation
Stoppage
43
E7
Not Prepared
Fan Operation
44
E8
Control at Heating
Thermo-OFF
45
E9
Not Prepared
46
EA
Not Prepared
Fan Operation
47
Eb
Control at Cooling
Thermo-OFF
Forced Thermo-ON
48
EC
Stoppage at Cooling
49
Ed
Not Prepared
Automatic Fan
50
EE
Speed Control
51
F1
Not Prepared
Remote Control
52
F2
Main-Sub Setting
53
F3
Not prepared
54
F4
Not prepared
55
F5
Not prepared
56
F6
Not prepared
57
F7
Not prepared
Lock Function for
58
F8
Operation Mode
Selection
Lock Function for
59
F9
Temperature Setting
Lock Function
60
FA
for Fan Speed
Selection
Lock Function
61
Fb
for Swing Louver
Operation
Cooling Lower
62
FC
Limit for Setting
Temperature (*4)
Heating Upper
63
Fd
Limit for Setting
Temperature (*5)
64
FE
Not Prepared
Lock Function for
65
FF
Timer
After at least 3 minutes from the power ON, change the optional setting.
When changing "CF" setting (change of louver swing range), restore the
power supply or allow the louver to make one complete swing fully in the
auto swing mode to apply the optional setting.
The optoinal settings are different according to the indoor and outdoor
unit models. Check to ensure that the unit has the optional setting or not.
Record the setting conditions for each optional setting in the "Setting"
column of the table.
Setting
Contents
Condition
Not Used
00~07
(Use as 00 conditions)
KPI:
Automatic Ventilation
00
Ventilation by Total
01
Heat Exchanger
Bypass Ventilation
02
(No Total Heat
Exchanging)
Econofresh:
00
Not available
01/02
All fresh mode
00
Not Available
01
Available
00
Not Used
01
(Use as 00 conditions)
KPI:
00
Standard
01
30 min.
02
60 min.
Econofresh:
00
Standard
01/02
CO
Sensor
2
00
Not Used
01
(Use as 00 conditions)
00
Not Available
01
60 min.
02
120 min.
00
Not Used
-
01
(Use as 00 conditions)
00
Not Available
01
Available
00
Not Used
-
01
(Use as 00 conditions)
00
Not Used
01
(Use as 00 conditions)
02
00
Not Available
01
LOW
02
SLOW
00
Not Available
01
Available
00
Not Used
01
(Use as 00 conditions)
00
Not Available
01
Available
-
00~0B
Not used
00
Main
×
01
Sub
-
00~01
Not used
-
00~03
Not used
-
19~30
Not used
-
17~30
Not used
-
00~01
Not used
Not Available
00
×
Available
01
(Factory-Setting)
Not Available
00
×
Available
01
(Factory-Setting)
Not Available
00
×
Available
01
(Factory-Setting)
Not Available
00
×
Available
01
(Factory-Setting)
00
Standard
01
Lower Limit +1ºC
02
Lower Limit +2ºC
×
09
Lower Limit +9ºC
10
Lower Limit +10ºC
00
Standard
01
Upper Limit –1ºC
02
Upper Limit –2ºC
×
09
Upper Limit –9ºC
10
Upper Limit –10ºC
00
Not Used
-
01
(Use as 00 condition)
02
Not Available
00
×
Available (Factory-
01
setting)