Descargar Imprimir esta página

HIKOKI RP18DA Instrucciones De Manejo página 13

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 54
Important notice on the batteries for the HiKOKI
cordless power tools
Please always use one of our designated genuine
batteries. We cannot guarantee the safety and
performance of our cordless power tool when used
with batteries other than these designated by us, or
when the battery is disassembled and modifi ed (such
as disassembly and replacement of cells or other
internal parts).
GUARANTEE
We guarantee HiKOKI Power Tools in accordance with
statutory/country specifi c regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling instruction,
to a HiKOKI Authorized Service Center.
Information concerning airborne noise and vibration
The measured values were determined according to
EN60335-2-69 and declared in accordance with ISO 4871.
Measured A-weighted sound power level: 84 dB (A)
Measured A-weighted sound pressure level: 73 dB (A)
Uncertainty K: 2 dB (A).
Wear hearing protection.
NOTE
Due to HiKOKI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.
TROUBLESHOOTING
Reduction in suction power:
See the instructions in CLEANING.
Is the fi lter dirty? - clean.
Dust bag full? - replace.
Tank full? - empty.
Nozzle, tubes or hose blocked?- clean.
Is the battery weak? - Charge/replace battery.
Device will not start:
Is the battery empty? - Charge/replace battery.
Water level detection active - empty tank, set switch to
"0" and restart the vacuum at level "I" or "II".
Particles are discharged at the outlet:
Is the fi lter defective? - Check the fi lter and replace if
required ("2. Replacing the fi lter" of "MAINTENANCE
AND INSPECTION").
The device has shut down by itself:
Causes and remedies:
Battery almost fl at: (the electronics prevent the battery
form discharging totally and avoid damage). If the
capacity indicator fl ashes after pressing the battery
button to display the battery capacity, then the battery
is almost empty and must be recharged.
Battery is not inserted properly: Check and correct.
Long continuous overloading of the device will activate
the temperature cut-out.
Leave the device or battery to cool.
Water level detection active - empty tank, set switch to
"0" and restart the vacuum at level "I" or "II".