Friedrich DDC1 Dry Contact Manual De Instrucciones página 12

Publicidad

Idiomas disponibles

Idiomas disponibles

Setting and using method
■ Flow Chart for 'SETTING_SW'
-. When not using WIND signal
Use WIND Signal?
NO
Set the switch '0 ~ 7'
YES
Use Thermal function?
NO
Set the switch '0 ~ 3'
YES
Use Operation mode?
NO
Set the switch '0 ~ 1'
Use Dry Contact
Control Priority?
NO
YES
Switch 0
Switch 1
-. When using WIND signal
Use WIND Signal?
YES
Set the switch '8 ~ F'
YES
Use Thermal function?
NO
Set the switch '8 ~ B'
YES
Use Operation mode?
NO
Set the switch '8 ~ 9'
Use Dry Contact
Control Priority?
NO
YES
Switch 8
Switch 9
Notes
• When you change a function with remote control without setting Dry_contact control priority the display
condition between remote control and controller can be different.
12 Dry contact for thermostat
Set the switch '2 ~ 3'
Use Dry Contact
Control Priority?
NO
YES
Switch 2
Switch 3
Set the switch 'A ~ B'
Use Dry Contact
Control Priority?
NO
YES
Switch A
Switch B
Set the switch '4 ~ 7'
YES
Use Operation mode?
NO
Set the switch '4 ~ 5'
Use Dry Contact
Control Priority?
NO
YES
Switch 4
Switch 5
Set the switch 'C ~ F'
YES
Use Operation mode?
NO
Set the switch 'C ~ D'
Use Dry Contact
Control Priority?
NO
YES
Switch C
Switch D
Set the switch '6 ~ 7'
Use Dry Contact
Control Priority?
NO
YES
Switch 6
Switch 7
Set the switch 'E ~ F'
Use Dry Contact
Control Priority?
NO
YES
Switch E
Switch F