Operation
6. Turn the device(s) on. For protection against possible electrical
shock hazards, if the Inverter is operated in wet or damp
conditions, a user-supplied, portable GFCI (ground fault
circuit interruptor) must be connected between each Inverter
receptacle and the equipment it powers. The following receptacle
manufacturer/model series have been tested and recommended:
· Hubbell GF8300
· Leviton 6598
· Eaton TWRSGF20
7. To disconnect, reverse the above procedure.
8. Remote Control (Optional): Ensure the inverter power switch is
in the OFF position prior to connecting the remote cable. Press
the I/O button to turn ON the inverter. The green power status
LED will illuminate to indicate it is working. You can then power
the inverter ON/OFF from a remote location with the included
PINVSWRM remote. This remote switch can be mounted in the
vehicle or a permanent mount application (see Mounting section
for more information). The green LED on the remote will illuminate
to indicate the inverter is in the ON operating mode. The Fault LED
will illuminate an issue with its operation. See Troubleshooting/
Maintenance section to identify the fault and ways to correct it.