SPECIFICATIONS
Part Number
SBI12 (*D)
System Voltage
12 V
ON Volts
13.2 V
OFF Volts
12.6 V
Turn ON Delay
Turn OFF Delay
Max. Cont. Current
Max. Inrush Current
Standby Current
PRIOR TO INSTALLATION
MOUNTING
ƒ Mount the Smart Start SBI securely in a convenient location near the start
battery bank.
ƒ Do not mount in direct engine heat.
RECOMMENDED FUSES
REDARC Fuse Kits are recommended as they contain high quality, reliable
fuses and fuse holders.
SBI12 / SBI24: FK60 MIDI 60 A Fuse Kit
SBI212 / SBI242: FK100 MEGA 100 A Fuse Kit
CABLE SIZES
Model
Wire Length
SBI12 / SBI24
SBI212 / SBI224
INSTALLATION
Override
Wire
(BLUE)
Start
Auxiliary
Terminal
Terminal
Ground
Wire
(BLACK)
Mounting
Point
WIRING DIAGRAM
1. Make sure the auxiliary battery negative is properly grounded to the vehicle
chassis. (1)
2. Ground Connection. Connect the Smart Start SBI ground terminal to
chassis ground. Remove any paint to ensure a good ground connection.
5
Start
Battery
SBI24 (*D)
SBI212 (*D)
SBI224 (*D)
24 V
12 V
26.4 V
13.2 V
25.4 V
12.6 V
5 sec
10 sec
100 A
200 A
400 A
600 A
< 5 mA
Start Feature with Push button Override
Circuit Breaker /Fuse
Up to 3 m
100 A
3 m to 6 m
100 A
Up to 3 m
200 A
3 m to 6 m
200 A
Start
Terminal
Auxiliary
Terminal
Mounting
Point
Override
Wire
(BLUE)
Fuse*
3
(with holder)
Override
Wire
SBI
Part Number
24 V
Dimensions
26.4 V
25.4 V
Weight
Warranty
Standards
*D indicates Dual Sensing Models.
Voltages Specified are ±0.1 V
MIDI Fuse with Holder
Wire
Circuit Breaker /Fuse
19 mm² (4 B&S)
32 mm² (2 B&S)
32 mm² (2 B&S)
40 mm² (1 B&S)
Ground
Wire
(BLACK)
STANDARD WIRING
ƒ Ensure adequately sized cable is used.
ƒ Ensure the auxiliary battery is properly grounded to a common chassis
earth point.
ƒ Ensure the SBI ground wire is making good contact with the chassis ground
point.
ƒ When using fuses make sure that the fuse makes a good low resistance
connection.
ƒ Fuse/Circuit Breaker ratings are dependent on the type of installation and
the size of the loads.
NOTE: A good ground will ensure correct switching voltage. (2)
3. Select correct Circuit Breaker/Fuse sizes and install at battery end of both
positive cables. (3)
4. Connect the cables in the order shown below. (4, 5, 6, 7)
6
2
4
SBI12 (*D)
SBI24 (*D)
75 × 70 × 80 mm
(3" × 2.8" × 3.2")
200 g (0.4 lbs)
2 years
CE, C-Tick, AS/NZS CISPR11:2004, UKCA
MEGA Fuse with Holder
No Override
Wire
60 A
8 mm² (8 B&S)
60 A
13 mm² (6 B&S)
120 A
19 mm² (4 B&S)
120 A
25 mm² (3 B&S)
Fuse*
3
(with holder)
7
Auxiliary
Battery
EN English | 3
SBI212 (*D)
SBI224 (*D)
90 × 95 × 100 mm
(3.5" × 3.7" × 3.9")
600 g (1.3 lbs)
Fuse Assembly
Main Stud Torque
5 — 6.2 Nm
5 — 6.2 Nm
6.5 Nm max.
6.5 Nm max.
Circuit Breaker*
Loads
1