Display stability
In the Celsius state: When the temperature measured by the temperature probe
is within ± 1 ° C of the set temperature, the temperature display will display the set
temperature value.
In the Fahrenheit state: When the temperature measured by the temperature
probe is within ± 2 ° F of the set
temperature, the temperature display will display the set temperature value
Error code
LL: When the temperature measured by the temperature probe is lower than 0 °C ,
"LL" is displayed, flashing, and the cooling is stopped.
When the temperature probe is short-circuited or disconnected, the setting
temperature value is displayed, the compressor will work for 15 minutes and stop
for 18 minutes.
When the temperature measured by the temperature probe is higher than
37 °C,the setting temperature value is displayed,the compressor will work for 15
minutes and stop for 18 minutes Forced defrosting function.
When the compressor works for 12 hours, the compressor will stop working for 40
minutes.
Memory function
The control board is re-energized after each power-off, the temperature setting
value, Fahrenheit/Celsius state will be the same as before the power-off, and the
length of power-off time is not limited.