CONVERSION
INSTRUCTIONS
Before starting the conversion,
make sure
all control knobs are in the OFF position,
LP tank valve is closed, and tank is
disconnected
from regulator
and removed
from grill. Next, open all lids and remove
warming
racks, cooking
grids, and heat
diffusers.
Orifice required:
Main Burner: D = 1.37 mm x 3
Searing
Burner: D = 1.44mm x 1
Side Burner: D = 1.31mm x 1
Main Burner Conversion
,
Remove the R pins at the back of main
burners to detach burners from bracket.
Lift back of main burners while sliding
burners out of firebox, disengaging
main
burners from valves. (Fig. 46)
--
R pin
Back of Firebox
Fig. 46
Orifice
2. Insert the provided
orifice removal tool (B)
into burner openings
and unscrew orifices
from ends of valves. (Fig. 47)
Fig. 47