5.
Application
F5LM single-lever mixer with mixing cartridge with ceramic disks and thermostatic
scald protection according to DIN EN 1111, preset to a maximum of 41°C for the
fitting unit. For connection to hot and cold water supply.
With one connection above the other. Fitting housing made of low-lead brass, in
accordance with the requirements of the TrinkwV and DIN 50930-6
recommendations.
6.
Technical specifications
Recommended flow
pressure:
Maximum operating
pressure:
Volumetric flow:
Calculation of flow rate:
7.
Scope of delivery
Quantity
1
1
8.
Dimensions
9.
Installation example
10. Assembly
Important!
Note the installation position of the filters.
10.1 Insert the filters (a).
Important!
Take care that the hole of the tension bolt (b) is vertically aligned.
10.2 Insert the fitting (c) and secure with the grub screw (d).
1-5 bar
10 bar
0.06 l/s at a flow pressure of >1.0 bar
0.06 l/s
Name
F5LM single-lever mixer
Installation and operating instructions
0.06 l/s