Initial Setup
Connect the Shop Exhaust System
The vent system on the back of the unit pulls
heated air from the unit, dilutes the heated air
with fresh air from the room, and exhausts the air
out the 102 mm (4-inch) exhaust port on the back
of the unit.
The vent system is activated when the internal
temperature of the unit is greater than 93°C
(200°F).
1. Connect shop exhaust to the standard 102 mm
(4-inch) connection on the bottom of the vent
system. See Figure 2.
Electrical Connections
1. Connect the power plug from the vent system
to the outlet on the control box. See Figure 2.
2. Connect the power plug from the unit to a
dedicated 240 VAC, single-phase, 50 amp,
electrical outlet.
Avoid running the power supply cord close to
the side of the unit. The high temperature of
the unit could damage the cord insulation.