Control panel / Operation instruction
Power
Press the Power Button to activate the device.
Press the Power Button again, the device turns off.
Note: When the power light is flashing, the device is in defrost mode.
MODE
Press the MODE Button to select between Smart and Air Purifying.
Smart Mode: The device will start dehumidifying when the humidity increases to 5%
above the desired humidity and will stop when the humidity drops to 5% below the
desired humidity. Use the humidity button to adjust the desired humidity
Fan Mode/ Air Purifier Mode: The fan will run with no dehumidifying effect. This is
ideal when you only want to use the device as an air purifier. This can also be used in
combination with the ioniser function.
Humidity setting
(Only for MODE program: Smart Mode)
By pressing the Humidity Button, you can select the desired humidity level by
pressing this button repeatedly until the required humidity level is displayed
(from 35% to 80% in increments of 5%).
Once you select your desired humidity level, simply stop pressing the button and
your humidity level will be set. When the humidity level in the room reaches the set
humidity level, the device will stop dehumidifying and it will only purify air.
When the room's actual humidity level increases again above your set humidity level
then the device starts dehumidifying again.
This button is also used to set the duration of the timer after pressing the TIMER
button.
UV and ION
After pressing once, the UV function is switched on.
After pressing twice the ION function is switched on.
After pressing three times, the ION and UV functions are switched on.
After pressing four times, the UV and ION functions are switched off.
Timer
Press TIMER button to program timer. When the timer is activated, the "TIMER" lamp
lights up. Before programming the timer, check that the timer function is not activated
(the light must be off). Following timer programs are available.
Power-on function: While the device is in standby, press the Timer button and then
use the button
to set the number of hours you want the unit to start (1~24 hours).
Power-off function: While the device is running with the desired settings, press the
TIMER button and then use the button
to set the number of hours after which you
want the device to stop (1~24 hours).