Following are a series of problems that may occur due to
incorrect installation or maintenance or
improper use, possible negligence or due to filter or part wear.
PROBLEM
CAUSE
Water does not run from
• Cartridge clogged.
faucets.
• Bowl broken.
• Cut-off valves and/or
By-pass closed.
Unfiltered water runs from
• Cartridge broken.
faucets.
• Spring broken.
• Cartridge gasket ruined.
• By-pass valve open.
The cartridge does not
• Insufficient pressure in
clean during self-cleaning
the bowl.
operation.
• Cartridge not correctly
positioned in the bowl.
Water leaks between the
• Bowl o-ring ruined.
filter head and bowl.
Water leaks from connec-
• Sealant (TEFLON)
tions between pipes and
insufficient.
from the sides of the filter.
Water leaks between the
• Drain valve gasket
bowl and drain valve.
damaged.
The descriptions and photographs contained in this product specification sheet are supplied by way of information only and are not binding. Watts Industries reserves the right to carry out
any technical and design improvements to its products without prior notice. Warranty: All sales and contracts for sale are expressly conditioned on the buyer's assent to Watts terms and
conditions found on its website at www.wattswater.eu. Watts hereby objects to any term, different from or additional to Watts terms, contained in any buyer communication in any form,
unless agreed to in a writing signed by an officer of Watts.