NOTE
The receiver may only be connected directly to screens with a hanging width
of less than 5m that are equipped with a 4-wire cable outlet. Please refer to the
„Connection" diagram for the connection method.
Observe
the
above
Install the receiver with cables pointing downward to prevent water in-
gress.
Do not install the receiver on/near metallic surfaces (interference).
Minimum height of the receiver to the fl oor: 150 cm.
Minimum distance of the receiver to the ceiling: 30 cm
Minimum distance between receiver and remote control: 30 cm
Minimum distance between two receivers: 20 cm
Do not forget to connect the ground
ALWAYS disconnect the power supply before working on electrical
equipment.
Make sure there is no tension / pull on the cables
Be sure to get help from an electrician if you are are inexperienced in
connecting electrical wires!
OPERATION
Info: Longest Running time 4 minutes, then the protection
circuit cuts in.
Up
Stop
1. Programming:
Down
Programming
button
safety
instructions
Press the „left" or „right" button on the remote control
to select the channel to be programmed (only
multi-channel). For the 1-channel remote control go
directly to the next step.
Press the programming button on the receiver 1x to
switch to programming mode (the green LED fl ashes).
(One receiver can be paired with up to 20 transmitters).
Within 10 seconds press the „up" button on the remote
control or „programming button" on the back of the
remote control. The green LED on the receiver fl ashes
quickly for 1 second.
Programming completed!