4
User menu settings
The user can adjust the following settings:
■ Temperature unit (°C / °F), display shows "Tum"
■ Display back-light, display shows "Dim"
AUTO
AUTO
MENU
6
MENU
Press and hold buttons 6 and "MENU" for 3 sec.
X
6 +
– The user menu opens.
Press button "Recirculation" or "Cooling" to
X
switch between menu items.
MENU
Press button "MENU" to select menu item.
X
Press button "Recirculation" or "Cooling" to ad-
X
just the parameter.
MENU
Press button "MENU" to save the parameter val-
X
ue.
Cool Top
5
Error codes
If an error occurs the display
shows an error code.
Error
Description
code
033
Empty refrigerant cir-
cuit
118
Short circuit on one
of the digital outputs
120
Water valve feedback Check water valve and its con-
125
Short circuit with
sensor
127
Short circuit with
sensor
129
Short circuit with
sensor
130
Short circuit with
sensor
132
Short circuit with
transducer
133
Short circuit with
transducer
143
Broken connection
with sensor
145
Broken connection
with sensor
147
Broken connection
with sensor
148
Broken connection
with sensor
150
Broken connection
with transducer
151
Broken connection
with transducer
162
Battery overvoltage
163
Battery undervoltage Check battery. Power supply volt-
164
Transducers supply
(5 V) undervoltage
167
Overcurrent fresh air
motor
168
Overcurrent water
valve
Tbl. 01: Error codes
Troubleshooting
Check refrigerant charge. Check
refrigerant leakage. Refill.
Check digital output and relays.
nections
Check NTC 2 Supply air tempera-
ture sensor
Check NTC 1 Internal tempera-
ture sensor
Check NTC 3 External tempera-
ture sensor
Check NTC 4 Internal auxiliary
temperature sensor
Check low pressure transducer
connection
Check high pressure transducer
connection
Check NTC 2 Supply air tempera-
ture sensor
Check NTC 1 Internal tempera-
ture sensor
Check NTC 3 External tempera-
ture sensor
Check NTC 4 Internal auxiliary
temperature sensor
Check low pressure transducer
connection
Check high pressure transducer
connection
Check battery. Power supply volt-
age above 16 V (12 V) or 32 V
(24 V).
age below 9 V (12 V) or 18 V
(24 V).
Check transducers supply line.
Power supply voltage below
4,95 V.
Check motor and its connections.
Current over 1.5 A.
Check water valve and its con-
nections. Current over 1.5 A.
6